1
2
Figure 2. 440V Power Panel No. 4
5.
Ensure that valve CA-48, SVCE AIR TK DR (figure 3, item 1) is CLOSED.
6.
CLOSE valves CA-13, SVCE AIR TK INL (figure 3, item 2), CA-51, AUTO DR (figure 3, item 3), and CA-14, SVCE AIR TK
OUT (figure 3, item 4).
7.
CLOSE valves CA-40, SVCE AIR TK INL (figure 4, item 1) and CA-39, SVCE AIR TK INL (figure 4, item 2).
8.
Ensure that valves CA-47, STG AIR TK DR (figure 3, item 5) and CA-46, STG AIR TK DR (figure 3, item 6) are CLOSED.
9.
CLOSE valves CA-50, AUTO DR (figure 3, item 7) and CA-49, AUTO DR (figure 3, item 8).
10. CLOSE valves CA-11, STG AIR TK INL (figure 3, item 9) and CA-12, STG AIR TK INL (figure 3, item 10).
11. CLOSE valves CA-1and CA-2, COV COMPR DISCH (figure 5, item 1), and CA-87 and CA-88, COV COMPR DISC
(figure 5, item 2).
12. Ensure that valves CA-89 and CA-90, COV COMPR DISCH (figure 5, item 3), and CA-93 and CA-94, MOISTURE SEP DR
(figure 5, item 4) are CLOSED.
13. CLOSE valves CA-4, STG AIR TK OUT (figure 3, item 11) and CA-3, STG AIR TK OUT (figure 3, item 12) at the starting
air receivers (figure 3, item 13).