Figure 5. Pump Drive Engine and Firefighting Pump Valve Locations
PUMP DRIVE ENGINE SHUTDOWN
1.
To unload and cool down the pump drive engine:
a.
Move the governor control lever (figure 6, item 1) to half engine speed position.
b.
Place the power take-off control lever (figure 6, item 2) in the disengaged (aft) position.
! CAUTION
Stopping the engine without a cool down period may cause accelerated wear of engine compo-
nents. Follow the stopping procedure to avoid damage to the engine.
c.
Allow engine to idle with no load for at least 5 minutes.
d.
Pull upward on the governor control lever (figure 6, item 1) and move the lever to OFF.
e.
Place the OFF-RUN-START toggle switch (figure 6, item 3) to OFF.
f.
Push in the START/STOP pushbutton (figure 6, item 4).
0109 00-4