Custom Search
 
  
 
TM 55-1925-273-10-2
0137 00
Table 1. Preventive Maintenance Checks and Services Including Lubrication (continued)
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
WARNING
FIRE STATIONS
During inspections, immediately report
any defects to your supervisor and
correct without delay, or refer to unit
maintenance.
29
During
2.0
Hose and
a. Inspect the fire hose in the hose rack
Hose is
Connection
for tears, fraying, or cuts.
unserviceable.
b. Check hose connections for tightness.
Connections will
not attach properly.
30
During
0.7
Nozzle
Check nozzle and nozzle handle for proper
Nozzle is
operation.
unserviceable.
Hose Rack
Nozzle
Fire Hose
31
During
0.2
PORTABLE FIRE  a. Inspect for tight mounting, full charge,
Extinguisher
EXTINGUISHERS
corroded nozzles, and closed valves.
discharged or
damaged.
Line
b. Verify that certification information is
Extinguisher is
Nozzle
correct and that the seals have not been
damaged, the seal is
tampered with. Direct particular
broken, and/or the
attention to extinguisher lines and
certification is out
nozzles in the engine room, checking
of date.
damage.
Portable Fire
Extinguisher
0137 00-15


 