Custom Search
 
  
 
TM 55-1925-273-10-2
0138 00
Table 1. Preventive Maintenance Checks and Services Chart (continued)
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
3
Before
0.5
TANK LEVEL
Observe level at remote indicator.
INDICATOR
Compare reading with receiver panel in
PANEL AND
EOS. Report any differences to unit
RECEIVERS
maintenance.
TLI Remote Indicator
4
Before
0.9
LUBE OIL
a. Visually inspect pump for leaks, loose
Pump is damaged.
TRANSFER PUMP
connections, and damage.
b. Check strainers for obstructions.
c. Grease two motor fittings with 1 to 2
strokes of general purpose grease.
d. Grease single pump fitting with 1 to 2
strokes of general purpose grease.
5
Before
2.0
LUBE OIL
Visually inspect manifold for cracks,
Class III leaks
MANIFOLD AND
leaks, and secure mounting. Visually
or loose mounting.
PIPING
inspect all lube oil system piping for
leaks and damage.
Lube Oil Transfer
Lube Oil Transfer
Pump Discharge
Pump Differential
Pressure Gauge
Pressure
Lube Oil Manifold
And Piping
Strainer
Piping
Coupling
Pump
Electric
Motor
Lube Oil
Grease Fitting
Transfer Pump
0138 00-2


 