Custom Search
 
  
 
TM 55-1925-273-10-2
0148 00
Table 1. Preventive Maintenance Checks and Services Including Lubrication (continued)
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
EMERGENCY
STOP SWITCHES
3
Before
0.2
Fuel Oil Pumps
Inspect panels for obvious damage or
Any damage which
missing or broken switches.
could affect
operation.
4
Before
0.2
Engine Room
Inspect panels for obvious damage or
Any damage which
Ventilation
missing or broken switches.
could affect
operation.
5
Before
0.2
AMS 1 Fans
Inspect panels for obvious damage or
Any damage which
missing or broken switches.
could affect
operation.
6
Before
0.2
AMS 2 Fans
Inspect panels for obvious damage or
Any damage which
missing or broken switches.
could affect
operation.
Emergency Stop AMS 1
Supply Fan
Emergency Stop AMS 2
Supply Fan
Emergency Stop HVAC
Engine Room Supply
and Exhaust Fans
Emergency Stop Fuel/Oil
Transfer Pump Number 2
Emergency Stop Fuel/Oil
Transfer Pump Number 1