Tweet |
Custom Search
|
|
|
||
TM 55-1925-273-10-2
0150 00
Table 1. Preventive Maintenance Checks and Services Chart (continued)
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
8
Before
1.0
WALK-IN
Check room temperature at thermostat.
Temperature out of
FREEZER
Temperature should be 4F to 0F
range.
(-20 to -18 C).
9
Before
0.2
Freezer Alarm
Visually inspect for damage or missing
parts.
10
Before
0.2
Condenser Coil
Inspect condenser coil to make certain
that air flow is not hampered and that it is
clear of dust and debris.
11
Before
0.2
Deck Drains
Inspect and check that the deck drains are
serviceable.
12
Before
0.2
Interior Shelving
Check that interior shelving is clean and
dry.
13
Before
0.2
Evaporator Fan
Visually inspect the evaporator fan motors
Motors
to make certain that they are operational
and that the fans are tight and secure.
14
Before
0.2
Door Gaskets
Check that door gaskets are clean and
serviceable.
Door
Screws
Hinge Cover
Evaporator
Drain
Drain
Fans and Motor
Line
Line
Gasket
0150 00-3
|
||