Custom Search
 
  
 
TM 55-1925-273-10-2
0159 00
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
44
Weekly
1.0
PILOTHOUSE
Visually inspect for obvious damage,
Obvious damage or
ALARM PANEL
press the PRESS TO TEST button, and
alarms do not occur.
verify that alarm indications are
functional.
PRESS TO
TEST Button
45
Weekly
3.0
PILOTHOUSE
Inspect console for cleanliness. Clean as
Any critical control
CONSOLE
required. Look for any loose, missing,
or indicator that is
or broken switches or controls, gauges,
unserviceable.
indicator lights, or obvious damage.
Ensure that throttle controls operate
smoothly and do not bind.
Bow Thruster
Clearview Screen
Control Panel
CONTROL AIR PRESSURE
STBD
GAUGE and COMMAND
Pilothouse
TRANSFER
Console
EOT
Ship Whistle
Pull Valve
Remote Propulsion
Indicator Panel
0159 00-18


 


Privacy Statement - Copyright Information. - Contact Us