Custom Search
 
  
 
TM 11-5895-1847-12&P
0029 00
CRYPTO KEY ENTRY USING AN/CYZ-10 (SPECIAL ANCD)
1.
Turn on the ANCD, read RADIO/SOI/SUPERVISOR.
2.
Enter RADIO, read SEND/RECEIVE/DATABASE/SETUP/COMSEC/TIME.
3.
Enter COMSEC, read VG/LD/RV/AK/MK/VU.
4.
Enter LD, read SELECT TEK/KEK.
5.
Enter TEK.
6.
Select the desired GPS key, then press ENTER.
7.
Enter QUIT, read CONNECT ANCD TO RT - DO NOT COMPLY.
8.
Press the DOWN ARROW key (3), read Press LOAD ON RT- DO NOT COMPLY.
9.
Turn the PLGR on, wait for self-test to complete.
10. Connect ANCD to the J1 port (10) on the PLGR. GPS key transfers automatically. The ANCD reports: 1 KEYS
TRANSFERRED. The PLGR reports KEY LOADED.
11. Disconnect ANCD from the J1 port (10) on the PLGR.
MISSION DURATION WARNINGS
NOTE
Mission duration does not apply when Group Unique Variable (GUV) keys are used.
A second GUV may be loaded prior to expiration of the current GUV key.
1.
Enter a mission duration to limit the number of crypto keys stored in the PPS-SM. Mission duration only applies
when Crypto Variable Weekly (CVW) keys are used. The maximum duration for these keys is 42 days (six weeks
or current day + 41). Up to six CVW keys may be loaded in any order. After the mission duration is entered, the
PLGR may display a warning.
2.
The PLGR may warn the user that too few keys are loaded for the duration of the mission or that too many
are loaded.
END OF WORK PACKAGE
0029 00 3/4 blank


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business