4-18.1. SEWAGE SYSTEM VACUUM PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
CLEANING (Cont)
8.
a.
Glass
Unscrew from cover (21).
jar
(19)
and
gasket
(20)
b.
Filter
Unscrew.
element
(22)
c.
Nipple
Remove.
If necessary.
(23)
d.
Filter
Clean and install.
Use solvent and
element
air dry.
(22)
e.
Glass jar
Clean and reassemble
Use solvent.
jar
to cover (21).
(19),
and
gasket(20)
(20)
4-672


 