Custom Search
 
  
 
TM 55-1905-220-14-8
4-18.1. SEWAGE SYSTEM VACUUM PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR
9.
Oil
a.
Filler plug
Remove.
reservoir
(1), and
gasket (2)
b.
Cap (3),
Remove.
and gasket
(4)
c.
Glass
Remove.
clyinder
(5) and
gasket (6)
d.
Spring (7),
Remove.
and strainer
felt (8)
e.
Wick (24)
Remove.
and lower
cap (25)
4-673


 