Custom Search
 
  
 
TM 55-1905-220-14-9
4-66.2. TANK LEVEL INDICATION - TRANSMITTER - MAINTENANCE INSTRUCTIONS
a.
GENERAL.
(1)  The transmitter consists of a network of voltage divider resistors and magnetic reed switches which are
contained in silicon rubber potted in a mylar tube that is surrounded by a neoprene tube and all mounted in a
stainless steel tube. Electrical leads connecting to the resistors and magnetic reed switches are brought to
electrical connectors located at the bottom of the transmitter.
(2)  A cylindrical float assembly located on the stainless steel tube is free to move up and down the tube
within limits established by pairs of brackets that are integral with the transmitters. The bracket pairs on the
tube are used as mounting surfaces for the installation of transmitters in the fluid tank.
(3)  The transmitter is used in single-transmitter installation in which fluid levels at the top of the tank can
be indicated, but fluid levels can be indicated only to a minimum point that lies above the bottom of the tank.
4-1423


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business