Custom Search
 
  
 
TM 55-1905-222-14
2-9.2
Emergency Operation to Lower Ramp.  When the propulsion units cannot be operated, or a
malfunction in the hydraulic ramp system is encountered, the ramp can be lowered according to the following
procedure:
a.
Disengage both PTO clutch levers to stop ramp hydraulic pumps. Refer to figure in para. 2-1, item 58.
b.
Close upper shut-off valve (3) in the hand pump compartment.
c.
Open lower shut-off valve (4) in the hand pump compartment.
d.
Close hand pump bypass valve (5).
e.
Remove port and starboard load binders. Refer to figure in para. 2-4.3.1(d).
f.
Operate hand pump (6) with handle (7) until winch brake releases and ramp starts lowering.
g.
Stop ramp lowering by opening the hand pump bypass valve (5).
Change 6
2-64


 


Privacy Statement - Copyright Information. - Contact Us