Table 2-2. Operator/Crew Preventive Maintenance Checks and Service - CONT
B - Before
D - During
A - After
W - Weekly
M - Monthly
INTERVAL
PROCEDURES
EQUIPMENT IS
ITEM
ITEM TO BE
CHECK FOR AND HAVE REPAIRED
NOT READY/
NO
B
DA W M
INSPECTED
OR ADJUSTED AS NECESSARY
AVAILABLE IF:
44
Emergency
WARNING
Batteries
Do not smoke when observing
battery electrolyte level.
Batteries give off fumes that
can explode. Electrolyte is an
acid and can cause personal
injury if it contacts skin or
eyes. Wear approved goggles,
gloves, and apron.
Batteries,
Inspect batteries, terminals,
l
l
l
cables and
connections, cables and vent
terminals
caps for cleanliness and
tightness. Clean or tighten
terminal connections as
required. Clean battery as
required.
l Electrolyte
Check electrolyte level with
hydrometer.
Aft Main Deck
(Exterior)
45
Shore Power
l
Cable
WARNING
Defer PMCS when shore power
operation is in progress. High
voltages could cause serious
injury or death.
Visually check condition of
l
cable. Check for cracked or
damaged insulation.
Check condition of cable con-
l
nection. Ensure connector is
protected from moisture, dirt
buildup and corrosion.


 