TM 55-1905-223-10
(c)
If SW5 tanks are to be filled,
1
Open BB-9, SUPPLY TO SW-5S and SW-5P (4).
2
If port SW-5 tank is to be filled, open BB-4, ISLN TK SW-5P (40).
3
If starboard SW-5 tank is to be filled, open BB-5, ISLN TK SW-5S (39).
(d) If SW-8 tanks are to be filled,
1
Open BB-13, SUPPLY TO SW-8S and SW-8P (5).
2
If port SW-8 is to be filled, open BB-20, ISLN-TK SW-8P (35).
3
If starboard SW-8 is to be filled, open BB-21, ISLN-TK SW-8S (19).
(8)
Activate tank level indicator system.
(9)
On Bilge/Ballast Pump Motor Controller (FIGURE 2- 161), set circuit breaker (1) to ON position, press
START pushbutton (2).
(10)
When selected SW tank has reached the required level, press STOP pushbutton (3).
FIGURE 2-161. Bilge/Ballast Pump Motor Controller.
2-452


 