Custom Search
 
  
 
TM 55-1905-223-24-18-1
Service Sediment Strainer.
This task covers: a. Service.
INITIAL SETUP
Tools
Equipment Condition
None
E l e c t r i c a l power to lube oil purifier
turned OFF at P205 power/lighting
panel and tagged "Out of Service - Do
Not Operate."
Materials/Parts
Paper towels Item 16, Appendix C
Warning tag, Item 1, Appendix C
SERVICE
Close valve on inlet side of sediment strainer.
a.
b.
Close valve on outlet side of sediment strainer.
Loosen yoke screw (2) and swing yoke (1) off cover (3).
c.
Leave preformed packing on cover.
L i f t cover off sediment strainer.
d.
Pull straight up on steel basket handle (4) to remove steel basket (5).
e.
f.
Empty steel basket contents and wipe steel basket clean with paper towels.
Install steel basket in sediment strainer well; it must be centered and
g.
firmly seated.
h.
I n s t a l l cover (3).
i.
Swing yoke (1) over cover and secure yoke screw (2) hand tight.
j. Open inlet and outlet valves.
k. Operate and check for leaks.
2-217


 