f.
Unscrew retaining ring (6) and remove indicator light (7) from tension
indicator.
Unscrew retaining ring (8) and remove tension push switch (9).
g.
h.
Unscrew hexagon nut (10) and remove toggle switch (11).
i.
Unscrew retaining ring (12) and remove stop push switch (13).
j.
Unscrew retaining ring (14) and remove start push switch (15).
k.
Unscrew retaining ring (16) and remove indicator light (17) from run
indicator.
Repair at this level of maintenance is by replacement of indicator lights (5, 7,
and 17), push switches (9, 13, and 15), toggle switch (11), and electromagnetic
relays (18, 19).
a.
Install run indictor light (17) and secure with retaining ring (16).
b.
Install start push switch (15) and secure with retaining ring (14).
c.
Install stop push switch (13) and secure with retaining ring (12).
d.
Install toggle switch (11) and secure with hexagon nut (10).
e.
Install tension push switch (9) and secure with retaining ring (8).
f.
Install tension indicator light (7) and secure with retaining ring (6).
Install high temp indicator light (5) and secure with retaining ring (3).
g.
h.
Install electromagnetic relays (18, 19).
Connect electrical leads and remove
tags.
Connect electrical leads to run indicator (17), start switch (15), stop
i.
switch (13), toggle switch (11), tension switch (9), tension indicator (7).
and high temp indicator (5). Remove tags.
Close door (2) and secure with door fasteners (4).
j.
REPLACEMENT (FIGURE 2-131)
a.
Position control panel (1) on bulkhead and secure with four machine screws
(2).
b.
Connect electrical power cable (3) and remove tags.
c.
Restore power to control panel and remove tags.


 