Custom Search
 
  
 
TM 55-1905-223-24-18-1
Replace/Repair Power Distribution Panel L104.
2-180.
a. Removal, b. Repair, c. Replacement.
This task covers:
INITIAL SETUP
Tools
Equipment Condition
Main switchboard MN DECK LIGHTING
T o o l kit, electrician's,
PANEL L104 100AT circuit breaker
OFF and tagged "Out of Service -
Materials/Parts
Do Not Operate."  TM 55-1905-223-10.
Circuit breaker P/N Q215HM
Incandescent lamp P/N INX 3528
Incandescent lamp P/N A19
Fluorescent lamp P/N F20T12
Fluorescent lamp P/N F8T5
Fluorescent lamp P/N F15T8
Warning tag, Item 1, Appendix C
Death, serious injury, or equipment damage
can result from contact with live electrical
circuits. Before beginning work on this, or
any other electrical equipment, turn power
and control voltage circuit breakers OFF and
tag "Out of Service - Do Not Operate."
Refer to the procedures in paragraph 2-179 to replace and repair the fluorescent
and incandescent lamps, power distribution panel, door assembly, plug in breaker
unit and main interior lug.