i. Remove gas solenoid valve (1, Figure 3-56).
j. Remove water solenoid valve (2).
k. Remove gas connector (27, Figure 3-55).
l. Remove water connector (26).
m. Remove handle (20) and mode switch (21).
n. Remove fan housing (10) and fan blade (11).
o. Remove alternating current motor (12).
WARNING
Transformer assembly may contain electrical charges and must
be grounded with a shorting bar to prevent electrical shock.
p. Remove transformer assembly (13).
q. Remove terminal board (28), voltage link (29), and terminal studs (30, 31)
WARNING
Capacitors may contain electrical charges and must be
grounded with a shorting bar to prevent electrical shock.
r. Remove capacitor (32) and capacitor bracket (33).
s. Remove panel (14).
t. Remove fixed capacitors (15, 16).
u. Remove shunt assembly (17).
v. Remove bus bar (18).
REPAIR
Repair at this level of maintenance is by replacemept of: gasket (4, Figure 3-55), gas connector (27), water
connector (26), transformer assembly (13), capacitor (32), fixed capacitors (15, 16), gas solenoid valve (1,
Figure 3-56), water solenoid (2).


 