CAUTION
To prevent damage to the indicator or to avoid getting an incorrect reading, install
the dial indicator extension so that it clears the rocker lever. See FIGURE 3-22 .
NOTE
Both valves are closed when rocker levers are loose and can be moved from side
to side. If both valves are not closed, rotate the accessory drive one complete
revolution; align the "A" mark with the pointer again.
(c) Install the dial indicator (6, FIGURE 3-22) and the support (4) from the Injector Adjustment Kit so that
the stem (5) of the dial indicator is on top of the injector plunger flange on cylinder No. 3.
(d) Securely tighten the thumbscrew (1) and the hold down screw (2) in place.
(e) Loosen the thumbscrew (3) and lower the indicator against the injector plunger flange until the stem
(5) is fully compressed.
FIGURE 3-22. Installing Dial Indicator and Support .
(f) Raise the indicator (6) approximately 0.025 inch (0.653 mm), and tighten the thumbscrew (3) to hold
the indicator in position.
3-36


 