Custom Search
 
  
 
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
AIR CONDITIONING AND VENTILATION SYSTEMS PIPING, VALVES, STRAINERS,
HOSES, AND FITTINGS, REPLACE
INITIAL SETUP:
Personnel Required:
Tools and Special Tools:
Two Watercraft Engineers, 88L
Tool Kit, Mechanic's Rail and Marine
(Item 1, Table 1, WP 0230 00)
References:
Equipment Condition:
FM 55-502
TM 55-1905-242-24P (WP 0058)
Air conditioning seacock CLOSED, locked out,
and tagged out IAW FM 55-502
A/C PILOTHOUSE, A/CACCOM PORT SIDE,
A/C ACCOM STBD SIDE, A/C SEA WTR
COOLING PUMP circuit breakers set to OFF,
locked out, and tagged out IAW FM 55-502
WARNING
The seacock for the affected system must be closed before beginning replacement of
any raw water system piping, hoses, and/or valves. Failure to observe this warning can
result in flooding of the space, damage to the vessel, and serious injury or death to
personnel.
0137 00-1


 


Privacy Statement - Copyright Information. - Contact Us