0069 00
(3)
120V DISTRIBUTION PANEL No. 4. (ENGINE ROOM). (figure 15, item 3)
(4)
120V DISTRIBUTION PANEL No. 1. (GALLEY). (figure 15, item 4)
f.
In the emergency diesel generator room, at the 120V emergency load center distribution panel, set following circuit
breakers to ON:
(1)
MAIN DECK, 01 & 02 LEVEL EMEERGENCY LIGHTING PANEL No. 1. (figure 16, item 1)
(2)
ENGINE ROOM EMERGENCY DISTRIBUTION PANEL No. 1. (figure 16, item 2)
(3)
PILOTHOUSE EMERGENCY DISTRIBUTION PANEL. (figure 16, item 3)
(4)
EMERGENCY DIESEL GENERATOR SET BATTERY CHARGER. (figure 16, item 4)
(5)
EMERGENCY DIESEL GENERATOR JACKET WATER HEATER. (figure 16, item 5)
(6)
GENERAL ALARM BATTERY CHARGER. (figure 16, item 6)
(7)
RADIO ROOM ELEX DISTRIBUTION PANEL. (figure 16, item 7)
(8)
EXTERIOR EMERGENCY LIGHTING PANEL No. 2. (figure 16, item 8)
PHASEA
GROUNDDETECTION
PHASEB
PHASEC
PRESSTOTEST
PHASEA
PHASE B
PHASE C
LAPSE
1
2
2
1
4
3
3
8
4
7
6
5
Figure 16. 120V Emergency Load Center
Figure 15. Load Center Distribution Panel
Distribution Panel
0069 00-11


 