TB 600-1
c.
Position oil pan baffle rod
in one of the following
1.
Prime and run.
positions, depending on
2.
Prime and run
ambient temperature.
auxiliary fuel.
1.
Above OF.
(The slowing of the pump
2.
Below OF.
action indicates the
fuel system is primed).
d.
Position air cleaner intake
Note
shutter in one of the follow-
Preheat is not required
ing positions, depending on
when engine is hot.
ambient temperature.
d.
Move master switch to
1.
Above 25 F
the preheat position and
2.
Below 25 F
hold for one minute.
*e.
Position governor control in
govern position.
f.
Position remote-local switch
in local position.
g.
Position emergency run-stop
switch in the normal position.
CAUTION
NEVER HOLD THE START, STOP, OR MASTER SWITCH IN THE START POSITION LONGER THAN 15
SECONDS. LET THE STARTER COOL FOR ONE MINUTE BEFORE TRYING TO RESTART IT.
h.
Push the start/stop switch
e.
Move master switch to
to the start position. Hold
the start position and
until engine has started and
hold until engine starts
15 to 20 psi shows on the
and reaches operating
oil pressure gage.
speed.
If engine does not start within
If engine does not start
15 seconds repeat Step h.
or reaches operating
speed within 15 seconds
i.
Allow engine to warm up,
repeat Steps d and 3.
three to five minutes.
f.
Allow engine to warm up,
j.
Place AC circuit breaker in
three to five minutes.
the ON position
g.
Place AC circuit breaker
in the ON position.
Change 3 H-12