Tweet |
Custom Search
|
|
|
||
TM 11-5895-1847-12&P
OPERATOR AND UNIT MAINTENANCE
LCU 2000 GLOBAL MARITIME DISTRESS AND SAFETY SYSTEM
OPERATION UNDER UNUSUAL CONDITIONS
INITIAL SETUP:
Personnel Required
Seaman 88K
SEND DISTRESS USING THE INMARSAT-C SATELLITE COMMUNICATIONS SYSTEM
SEND IMMEDIATE DISTRESS MESSAGE
1.
Press the STOP (1) and ALARM (2) buttons on the transceiver simultaneously to send an immediate
MARITIME DISTRESS.
Press both keys for 5
seconds to send alarm.
On/Off
Power
Stop
Login
Send
Mail
Alarm
Alarm
Inmarsat-C Transceiver
SEA Inc.,
1
2
3
2C044-1
NOTE
After you have sent a maritime distress you may send a set or detailed message.
2.
Hold buttons for at least 5 seconds until the alarm indicator (3) starts flashing.