Custom Search
 
  
 
TM 11-5895-1847-12&P
OPERATOR AND UNIT MAINTENANCE
LCU 2000 GLOBAL MARITIME DISTRESS AND SAFETY SYSTEM
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Tools
General Mechanics Rail and Marine Tool Kit (Item 4, WP 0166 00)
Personnel Required
Seaman 88K
Equipment Condition
AC Generator Operating.
TROUBLESHOOTING PROCEDURE
SATELLITE COMMUNICATIONS SYSTEM DATA TERMINAL DOES NOT DISPLAY A VALID POSITION
SYMPTOM
Current position shown in data terminal display is invalid.
MALFUNCTION
Initial setup procedures are incorrectly entered.
CORRECTIVE ACTION
Perform initial set up of data terminal. (WP 0007 00)
SYMPTOM
Current position shown in communications PLGR display is invalid.
MALFUNCTION
Initial setup procedures are incorrectly entered.
CORRECTIVE ACTION
Troubleshoot communications PLGR for display of invalid position. (WP 0058 00)
SYMPTOM
Check operate/program switch on the communications interface and switchbox.
MALFUNCTION
Operate/program switch on the communications interface and switchbox is in the PROGRAM
(down) position.
CORRECTIVE ACTION
Place the operate/program switch on the communications interface and switchbox in the
OPERATE (up) position.
0077 00 1


 


Privacy Statement - Copyright Information. - Contact Us