Custom Search
 
  
 
0155 00
TM 11-5895-1847-12&P
2.
Drill and tap a 1/4-20 or 3/8-16 hole. Use thread cutting oil, drill, tap, tap wrench and drill set.
3.
Cut copper grounding strap (4), allowing enough length to reach from tapped hole to ground stud on equipment.
4.
Punch hole into end of copper grounding strap (4) corresponding with the size of the ground stud on the
equipment. Use punch and die set.
5.
Punch hole into opposite end of grounding strap (4) corresponding with the size of tapped hole (5) drilled in step
two. Use punch and die set.
6.
Expose bare metal immediately around tapped hole (5) using grinder to remove paint and primer. Use drill and
grinder attachment.
7.
Apply anti-sieze onto exposed metal.
8.
Insert bolt (1) through lock washer (2), washer (3), grounding strap (4) and into threaded hole (5).
9.
Tighten bolt (1).
10. Wipe off excess anti-sieze.
11. Remove nut and washers from ground stud on equipment.
12. Insert other end of grounding strap, washers and nut onto the ground stud on equipment.
13. Tighten nut.
INSTALL EXTERIOR GROUNDING STRAP
1.
Locate position to drill hole for the grounding strap (4).
1
2
3
4
5
2C153-1
2.
Drill and tap a 1/4-20 or 3/8-16 hole. Use thread cutting oil, drill, tap, tap wrench, and drill set.
3.
Cut stainless steel grounding strap (4), allowing enough length to reach from tapped hole to ground stud
on equipment.
0155 00 2


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business