TM 5-1940-277-10
TM 1940-10/1
Table 3-1. Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7.
ENGINE AUDIBLE ALARMS COME ON (NORMAL OPERATION)
Step 1. Turn OFF alarm mute switch (1) to turn off audible alarms.
Step 2. Check instrument panel low oil pressure warning lights (2) and high water temperature warning lights (3)
for appropriate engine to determine malfunction. Read appropriate gage. Oil pressure gage (4) should
be above 20 psi (1. 5 Kp/cm2). Water temperature gage (5) should be below 194 (90 ).
F
C
a. If problem is high water temperature, see Malfunction No. 4.
b. If problem is low oil pressure, see Malfunction No. 6.
3-11