Section III. OPERATION UNDER USUAL CONDITIONS
2-9. STARTING.
a.
Perform all of the Before (B) PMCS (para. 2-7).
CAUTION
If engine is operated with the hydraulic oil shut-off valve closed, serious damage to the main
pump will occur.
b.
Be sure the hydraulic oil shut-off valve is open.
CAUTION
Damage to starter could result if starter is engaged and engine does not start within 15 seconds.
c. With forward-reverse valve lever in neutral (center), turn start switch firmly until engine starts. If engine fails
to start within 15 seconds, release starting switch and wait 5 seconds before attempting to start again.
CAUTION
Operating engine without oil pressure will result in engine being damaged.
2-10. RUNNING.
CAUTION
Immediately upon starting engine, check hydraulic charge pressure gauge on control panel.
Charge pressure should be approximately 300 psi. If charge pressure is less than 200 psi., shut
engine down immediately and notify Unit Maintenance.
NOTE
Engine oil pressure should be between 43 and 65 psi.
a. Oil Pressure. Observe oil pressure gauge immediately after starting engine. If there is no oil pressure within
15 seconds after start-up, shut engine down, and notify Unit Maintenance.
2-13
|
||