TM 5-2805-261-13
LOCATION/ITEM
ACTION
REMARKS
3-15. FUEL PUMP MAINTENANCE -continued
CLEANING FUEL
WARNING
FILTER
Drycleaning solvent, P-D-680,
used to clean parts is poten-
tially dangerous to personnel
and property. Avoid repeated
and prolonged skin contact
by wearing rubber or non-
porous gloves when handling
the solvent or material wet
with drycleaning solvent. Wash
hands immediately after
exposure with soap and water
and use a lanolin based skin
cream to prevent skin drying.
Do not use near open flame or
excessive heat. Flash point of
solvent is 100 (38 ). Do
F
C
not work with solvent in a
closed room. Be sure there is
good ventilation or the solvent
vapors will build up in the air
and become a poisonous
mixture which can cause
physical injury or even death.
Filter element (4)
Wash in suitable solvent
using a soft bristle brush.
ASSEMBLY
1.
Filter element (4)
Install in pump cover (2).
2.
Pump cover (2)
Position on pump body (3).
3.
Mounting screw (1)
Install.
4.
Fuel line
Connect.
Clean up any spilled fuel with a clean lint-free rag.
5.
Fuel system
Prime.
Check for any leaks. Repeat procedure if fuel pump
leaks.
3-22