e. The Coolant System is shown in Figure 1-51. Coolant is circulated through the engine by a centrifugal-type
water pump. Heat is removed in a closed system by the heat exchanger. Control of the engine temperature is
accomplished by a thermostat which regulates the flow of the coolant within the cooling system.
f. Engine starting is provided by an Hydraulic Starting System. Engine speed is controlled by a mechanical
variable speed governor.
|
||