Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
130
MONTHLY
Pilot House
WINDSHIELD WIPER. Fill oil cup (15) with
Low oil level.
oil (MIL-L-9000H (SH)).
Remove cover (16) and lubricate internal
linkage with oil (MIL-L-9000H (SH)).
Inspect wiper blade (17) and replace when
Worn, cracked, or
damaged. Remove screw (18) to
torn.
disassemble.
131
MONTHLY
Above Galley and Mess
SEARCHLIGHT
Lamp fails to
function.
LUBRICATION. Lubricate trunnion bolts (24)
with oil (MIL-L-9000H (SH)). Grease fitting
(25) located at socket (26) with grease (MIL-
G-16456B (SH)).
Remove clamps (27) from center blade rod.
Then remove bearing housing covers (28).
Apply a few drops of oil (MIL-L-9000H (SH)),
into the hole in the hub of bearing housing
assemblies (29).
2-174 Change 4
|
||