TM 55-1905-219-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
170
ANNUAL
Engine Room
HYDROSTARTER FILTER.
Filter obstructed.
CAUTION
Do not attempt to change filter
element until the pressure in
the system is released.
Release pressure by loosening relief valve
(53) on the hand pump (54). Loosen bail nut
(55) and swing bail (56 aside. Remove cup
(57), filter (58) and gasket (59). Discard filter
and gasket. Clean cup (57) with compressed
air.
Reinstall in reverse order.
WARNING
Use eye protection when using
compressed air.
2-212 Change 4


 