TM 55-1905-219-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
170
Install new filter (58) and gasket (59) in cup
Continued
(57). Place bail (56) in position and tighten
bail nut (55). Close relief valve (53) on the
hand pump (54).
171
ANNUAL
Engine Room
HYDROSTARTER. Remove the
Filter obstructed.
hydrostarter from the engine for lubrication.
Before removing the hydrostarter release the
pressure in the system by means of the relief
valve (60) on the hand pump 61).
Then remove three bolts (62) and washers
(63) that attach the starting motor (64) to the
flywheel housing. Remove the starting motor
without disconnecting the hydraulic hoses.
Change 4 2-213