Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
172
ANNUAL
Engine Room
GOVERNOR OIL FILTER. Remove straight
Filter obstructed.
adapter (4), overflow reservoir tube (5), and
pipe reducer (6). Remove cover (7), gasket
(8) and filter (9). Install new filter (9) and
gasket (8). Replace cover (7), pipe reducer
(6), overflow reservoir tube (5) and straight
adapters (4).
173
ANNUAL
Engine Room
AIR BOX DRAINS. With the engine running,
check for flow of air from the air box drain
tubes (35). If the tubes are clogged, remove
along with inverted elbow. Clean and re-
install the air box drain tubes (35) and
inverted elbow.
Change 4 2-215


 