Custom Search
 
  
 
TM 55-1905-219-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
174
ANNUAL
Engine Room
HYDROSTARTER SYSTEM. Refer to Table
2-1 for maintenance on the Hydraulic
Reservoir.
Remove the Hydrostarter from the Generator
for lubrication. Before removing the
Hydrostarter release the pressure in the
system by means of the relief valve (37) on
the hand pump (38). Then remove three
bolts (39) and washers (40) that attach
starting motor (41) to the flywheel housing.
Remove the starting motor without
disconnecting the hydraulic hoses.
Apply grease (MIL-G-24139A (SH)) on drive
clutch pinion (42) to make sure clutch will
slide freely while compressing spring Also
apply grease to the fingers of clutch fork (4)
and on the spool of clutch yoke (44).
2-216 Change 4


 