Custom Search
 
  
 
TM 55-1905-219-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
180
ANNUAL
Anchor Winch
HYDROSTARTER FILTER.
Compartment
CAUTION
Do not attempt to change filter
element until system pressure
is released.
Release pressure by loosening relief valve
(33) on the hand pump (34). Loosen bail nut
(35) and swing bail (36) aside. Remove cup
(37), filter (38) and gasket (39). Discard filer
and gasket. Clean cup (37) with compressed
air.
Reinstall in reverse order.
Install new filter (38) and gasket (39) in cup
(37). Place bail (36) in position and tighten
bail nut (35). Close relief valve (33) on the
hand pump (34).
2-222 Change 4


 