Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
181
ANNUAL
Anchor Winch
HYDROSTARTER. Remove the
Compartment
hydrostarter from the engine for lubrication.
Before removing the hydrostarter, release
the pressure in the system by means of the
relief valve (40) on the hand pump (41).
Then remove three bolts (42) and washers
(43) that attach starting motor (44) to the
flywheel housing. Remove the starting motor
without disconnecting the hydraulic hoses.
Apply a grease (MIL-L-24139A (SH)) on
drive clutch pinion (45) so that it will slice
freely while compressing spring. Also apply
grease to the fingers of clutch fork (46) and
spool of clutch yoke (47).
Remove pipe plug (48) from starting motor
drive housing (44) and saturate shaft oil wick
(49) with engine oil. Re-install the plug (48).
After lubricating, install starting motor on the
flywheel housing and recharge the
accumulator with the hand pump.
Change 4 2-223
|
||