Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item to Check/
Not Mission
No.
Interval
Service
Procedure
Capable :
NOTE
183
Continued
Be sure strainer is free of diesel
oil before replacing.
Remove filler breather cap (3) and refill
hydraulic reservoir (1) with hydraulic fluid.
NOTE
Hydraulic fluid used in the
pump unit is MIL-H-46170, FRH,
Type 1.
Replace filler breather cap (3). Operate the
system and maintain the reservoir oil level.
CAUTION
Add hydraulic fluid to the
reservoir to maintain the proper
level as the system fills. The
reservoir holds 10 gallons
(37.85 liters). The system holds
30 gallons (113.55 liters).
Continue to operate system to purge air from
the lines for smooth and quiet operation.