5-24. HYDROSTARTER SOLENOID-MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
CLEANING
4. All parts must be thoroughly cleaned and kept clean duringinspec-
tion and assembly. Contamination in the unit will cause excessive
wear, leakage and decreased service life. Clean in accordance
with standard procedures for hydraulic parts. Do not usecompres-
sed air to dry parts unless the air is completely filtered in
order to remove water and contaminants.
REASSEMBLY
5.
NOTE
Coat all internal parts lightly with lubricating oil.
a. Push pin
Reassemble and insert
(25), and
into body (29).
spool (26)
b. Spring
Install in body (29).
Use new O-rings.
washer (24),
spring (23),
washer (22),
O-rings (21
and 20 ),
spring guide
(19), and
retaining
ring (18)
5-424


 