TM 55-1905-219-14-10
5-24. HYDROSTARTER SOLENOID-MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (Cont)
c.
Gasket
Reassemble.
Use new gasket.
(17),
adapter
plate,
(16), and
screws (15)
d. Gasket
Reassemble.
Use new gasket.
(10),
solenoid
mounting
plate (14),
screws
(12), and
(13)
e. Wire
Feed thru holes in
recepta-
gasket (17), adapter
cles (5
plate (16), gasket (10),
and 11)
and solenoid mounting
plate (14). Attach
wire receptacles (5 and
11) to solenoid (9).
f.
Gasket
Reassemble.
Use new gasket.
(10),
solenoid
(9), screws
(7), and
(8)