TM 55-1905-219-14-2
2-39. REMOTE OPERATION - GENERATOR #1 (Cont).
To avoid the possibility of damage to the generator, when indicator (6) is lit: circuit
breaker (7) must be in the OFF position, before placing circuit breakers (8 and 9)
in the ON position.
Shore power is being supplied to the vessel. Shore power indicator (6) is lit, and
circuit breaker (7) is in the ON position.
(4)
Place the shore power circuit breaker (7) in the OFF position.
NOTE
Shore power indicator (6) will remain lit.
(5)
When the generator is at 450V and 60 hz, place the generator #1 main circuit breaker (8) in the ON position.
(6)
Place the distribution bus circuit breaker (9) in the ON position.
(7)
Place the auto/manual switch (10) in the AUTO position.
GENERATOR #1 - REMOTE
2-278
|
||