Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-2
2-67.
ANCHOR "A" FRAME.
a. The anchor "A" frame is powered by the centralized hydraulic system. Prior to operation the preliminary
adjustments in paragraph 2-64 must be performed.
b. The anchor "A" frame is one of many components required for payout and inhaul of the anchor. Refer to
2-68.
STERN GATE LOWERING.
The stern gate is a hydraulically operated hinged gate which can be lowered to form a causeway between vessels
for moving cargo. To lower the stern gate proceed as follows:
NOTE
Prior to operation the preliminary procedures in paragraph 2-64 must be performed.
Do not attempt to lower the stern gate before energizing the central hydraulic
system.
Check hydraulic system, make sure it is not in operation and no other work is
being performed anywhere on the system.
a.
Engine Access Room.
Press the START switch (1) on the centralized hydraulic system.
3-368
|
||