TM 55-1905-219-14-2
2-73.
FRESH WATER SYSTEM (Cont).
(5) To Operate the System on Dockside Water:
The system can be operated on dockside water while in port.
The procedure is the same as the previous procedure with
the following exceptions:
(a) Place switch (27) on controller (28) in the OFF position.
(b) Close shut off valve (4) by rotating valve clockwise.
(c) Close pressure tank shut off valve (12) by rotating the valve clockwise.
(d) Open dockside water valve (6) by rotating valve counter-clockwise.
Check the dockside water pressure. Too much pressure could break the fill hose, or blow a fitting, gasket
or washer.
2-386