Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-2
2-97. PRESTART ADJUSTMENTS.
The following adjustments should be performed prior to starting the system. Refer to figure FO-50 for component
locations.
a.
Forward Engine Room.
(1)
Close sample/drain valve (1) at base of prefilter separator.
(2)
Close sample/drain valve (2) at base of 2nd stage separator.
(3)
Close sample/drain valve (3) at base of 3rd stage separator.
(4)
Close manual oil discharge valve (4).
(5)
Close manual bypass shut off valve (5).
(6)
Open manual shutoff valve (6).
(7)
Open intervessel shutoff valve (7).
(8)
Open intervessel shutoff valve (8).
NOTE
The following procedures, steps (9) thru (15), need be performed only when the
equipment is to be operated for the first time.
When removing covers, be careful not to damage the float of the air eliminator
valve (9) on the bottom of the cover.
(9)
Lift cam bar (10) and remove cover (11).
(10) Lift cam bar (12) and remove cover (13).
2-438
|
||