2-97. PRESTART ADJUSTMENTS (Cont).
(11) Lift cam bar (14) and remove cover (15).
(12) Tighten wing nuts securing elements.
Do not use a wrench to tighten wing nuts or the filter elements may be damaged.
(13) Close Intervessel shutoff valve (7).
(14) Fill prefilter primary separator (16) one-half to three-fourths full of clean water.
The pump (17) should contain water prior to initial startup. Water from separator
(16) will drain into pump.
(15) Replace covers (11, 13 and 15), secure with cam bars (10, 12, and 14).
(16) Place circuit breaker #9 on lighting distribution panel L-107 in the ON position.