Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-3
Table 3-35. Hydrostarter - Hand Pump Fails to Discharge Fluid -
Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Hand pump fails to discharge fluid (Cont)
Step 3.
Check for plugged reservoir screen.
Remove and clean the reservoir
screen, flush the reservoir
tank and reassemble. Refer
to Direct Support Maintenance.
Step 4.
Check for low fluid level.
See table 3-31, step 2.
Step 5.
Check for air in system.
To purge the hand pump of air:
a.
Relieve any system pressure,
then disconnect the outlet
hose from the hand pump.
3-124
|
||