Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-35. Hydrostarter - Hand Pump Fails to Discharge Fluid -
Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Hand pump fails to discharge fluid (Cont)
b.
Close the manual relief
valve and operate pump until
fluid is discharged when
stroking in both directions.
c.
Reconnect the outlet hose.
Step 6.
Check for dirt in pump.
See step 2.
Step 7.
Check for damaged piston seal rings.
Replace the seal rings.
Refer to paragraph 3-104.
3-125


 