TM 11-1905-219-14-3
Table 3-77. Anchor Winch Engine - Hydrostarter Fluid Emerges
Around Rubber Boot of Hand Pump - Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Fluid emerges around rubber boot of hand pump.
Step 1.
Check for damaged piston seal rings.
Replace the seal rings and leather back-up rings on the pump piston. Refer
to paragraph 3-179.
Table 3-78. Anchor Winch Engine - Hydrostarter Fluid Emerges From
Ends of Starter Control Valve When Starter Is Operated -
Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Fluid emerges from ends of starter control valve when starter is operated:
Step 1.
Check for damaged front control valve seal ring:
Operate the starter. If fluid emerges around front end of the control valve,
the seal ring is damaged. Refer to paragraph 3-176.
3-223