3-56.
SHAFT SEALS - MAINTENANCE INSTRUCTIONS.
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)
3. Wrap spring garter
(25) around sealing
element (27).
(a)
By crossing and
pulling cords man-
ually, hook together
the ends of the
spring garter (25).
(b)
Ease spring garter
Do not dis-
(25) down onto
turb the ce-
the sealing
mented joint.
element (27 ).
(c)
Remove the pulling
cord.
11. Sealing
Spring
1. Remove cord from the
element
garters
sealing element (26),
and carefully move it
to approximately 1/8
inch (0.3175 cm) from
the forward face of
sealing element (27).
2. Using a strong cord,
loop into each hook end
of spring garter (24).
3. Wrap spring garter
(24) around sealing
element (26).
(a)
By crossing and
pulling cords man-
ually, hook to-
gether the ends
of the spring
garter (24).
(b)
Ease spring garter
Do not dis-
(24) down onto the
turb the ce-
sealing element (26). mented joint.
(c)
Remove pulling cord.