Custom Search
 
  
 
TM 55-1905-219-14-4
3-56.
SHAFT SEALS - MAINTENANCE INSTRUCTIONS.
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)
12. Seal
Seal
1. Wipe clean all machined
Use MEK
housing
housing
surfaces of each seal
solvent.
housing (11).
Methyl Ethyl Ketone (MEK) solvent is a highly vola-
tile and flammable substance. DO NOT USE NEAR FIRE
OR FLAME. Provide adequate ventilation. Avoid pro-
longed breathing of vapor. Avoid repeated contact
with skin. Seal container when not in use.
2. Install hex bolts (16),
Be sure pre-
lockwashers (15) and
formed pack-
hex nuts (14), to se-
ing grooves
cure seal housing (11)
and bore
around shaft.
surfaces are
lined up.
3. Apply a thin film of
clean cup grease to one
split surface section
of seal housing (11).