TM 55-1905-219-14-4
3-56.
SHAFT SEALS - MAINTENANCE INSTRUCTIONS.
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)
4. Place cemented, pre-
formed packing (12)
onto seal housing (11).
5. Place cemented, pre-
formed packing (21),
onto seal housing (11).
6. Attach seal housing
Be sure sur-
(11) to inflatable
faces to be
ring housing (20)
joined are
with hex bolts (19),
free of dirt,
lockwashers (18), and
metal chips,
hex nuts (17).
etc.
Do not damage assembled sealing elements (26 and
27), during this operation.
13.
Gland
a.
gland
1. Wipe clean all mach-
Use MEK
ring
half-
ined surfaces.
solvent.
ring
(7)
2. Install bushings (13).
Methyl Ethyl Ketone (MEK) solvent is a highly vola-
tile and flammable substance. DO NOT USE NEAR FIRE
OR FLAME. Provide adequate ventilation. Avoid pro-
longed breathing of vapor. Avoid repeated contact
with skin. Seal container when not in use.
3. Apply a thin film of
clean cup grease to
one split surface sect-
ion of gland ring (7).
4. Place gland ring (7)
Be sure all
half around shaft.
machined sur-
faces line up.
3-1026


 